Data Description
================================
1. Overview
-----------
This folder contains the Excel data files corresponding to Figures 3-7.
The data include both theoretical calculation results and experimental measurement results related to biplane 3D SMLM.

File names generally follow the format:

FigXx_description.xlsx

where:
- X  = figure number
- x  = panel label (a, b, c, d, etc.)
- description = brief summary of the data content

Unless otherwise noted:
- um = micrometers
- nm = nanometers

2. Figure 3: Theoretical axial localization precision under aberration-free conditions
--------------------------------------------------------------------------------------
Fig3a_theoretical_axial_precision_vs_z_different_biplane_distance.xlsx
Contains theoretical axial localization precision as a function of z under different biplane distances.

Fig3b_theoretical_mean_axial_precision_vs_biplane_distance.xlsx
Contains mean axial precision as a function of biplane distance for different axial ranges.

Fig3c_theoretical_axial_precision_vs_z_biplane_distance_0p3to0p5um.xlsx
Contains theoretical axial localization precision versus z for biplane distances in the range of 0.3-0.5 μm.

Fig3d_theoretical_mean_axial_precision_vs_biplane_distance_0p3to0p5um.xlsx
Contains mean axial precision as a function of biplane distance for the refined range of 0.3-0.5 μm.

3. Figure 4: Theoretical axial localization precision under aberrated conditions
--------------------------------------------------------------------------------
Fig4a_theoretical_mean_axial_precision_vs_biplane_distance_aberrated.xlsx
Contains mean axial precision as a function of biplane distance in the presence of astigmatism.

Fig4b_theoretical_mean_axial_precision_vs_biplane_distance_aberrated.xlsx
Contains additional mean axial precision data as a function of biplane distance  in the presence of coma.

Note:
The dashed and solid curves shown in the figure correspond to different Zernike coefficients. The Excel files store the underlying numerical data.

4. Figure 5: Experimental biplane-distance measurement results
--------------------------------------------------------------
Fig5b_measured_biplane_distance_boxplot_data.xlsx
Contains experimental biplane-distance measurements used to generate the box plots for three sets of experiments across different groups.

Note:
The box plots are statistical visualizations generated from the measurement values stored in the Excel file. The Excel file is intended to contain the underlying grouped/raw values rather than only summary statistics.

5. Figure 6: Experimental axial localization results of fluorescent beads
-------------------------------------------------------------------------
Fig6a_actual_z_vs_localized_z_experimental_data.xlsx
Contains experimental axial localization data for fluorescent beads,
including actual z positions and localized z positions under different biplane distances.

Fig6b_experimental_coefficient_of_determination_data.xlsx
Contains coefficient of determination values for different datasets under different biplane distances.

Fig6c_experimental_corrected_residual_error_data.xlsx
Contains corrected residual error values for different datasets under different biplane distances.

Note:
Although Figure 6(a) shows a reference/fitted line, the Excel file contains only the experimental data points. The line in the figure was drawn as a reference relationship with slope = 1 and is not stored as a separate dataset.

6. Figure 7: Biological sample imaging results
----------------------------------------------
6.1 Whole-cell reconstructed images
These files contain the full-field 3D super-resolution reconstructed images of mitochondria for each biplane distance condition.

Fig7a_delta0p200_wholeFOV_xyz.xlsx
Whole reconstructed mitochondrial image for δ = 0.200 μm.
The image is color-coded by axial position (z, in μm).

Fig7b_delta0p380_wholeFOV_xyz.xlsx
Whole reconstructed mitochondrial image for δ = 0.380 μm.
The image is color-coded by axial position (z, in μm).

Fig7c_delta0p599_wholeFOV_xyz.xlsx
Whole reconstructed mitochondrial image for δ = 0.599 μm.
The image is color-coded by axial position (z, in μm).

6.2 Line profile and fitting results
For each biplane distance condition, the line profile figure includes three color-coded datasets, corresponding to three selected ROIs shown in the reconstructed image.
Each color represents one ROI and its corresponding line profile analysis result.

Fig7a_delta0p200_XXXROI_axialIntensityProfile.xlsx
Line profile data for three selected ROIs at δ = 0.200 μm.

Fig7b_delta0p380_XXXROI_axialIntensityProfile.xlsx
Line profile data for three selected ROIs at δ = 0.380 μm.

Fig7c_delta0p599_XXXROI_axialIntensityProfile.xlsx
Line profile data for three selected ROIs at δ = 0.599 μm.


